Skip to content
Integrated Energy Systems
0-2kW Single-Phase Micro Inverter

Residential energy storage

0-2kW Single-Phase Micro Inverter

Micro inverters from 500 VA to 2000 VA with module-level MPPT and rapid shutdown compliance.

Models

  • HJ-MG0003-W (500W)
  • HJ-MG0003-W (1000W)

Request a quote

Contact our sales team for pricing, lead times and configuration options.

Contact sales

Overview

A micro inverter range covering 500 VA to 2000 VA with module-level MPPT and monitoring for higher yield and easier maintenance. It meets North American rapid-shutdown requirements for rooftop safety.

Key features

  • Module-level MPPT and data monitoring
  • For modules from 360 W to over 600 W
  • Reactive power compensation (NB/T 32004-2018)
  • Rapid shutdown compliant for rooftop installations

Typical applications

Residential rooftops where module-level control and safety matter.

Technical specifications

Technical specifications — 0-2kW Single-Phase Micro Inverter
ParameterHJ-MG0003-W (500W)HJ-MG0003-W (1000W)
Input (DC)
Compatible Module Power (W)360~600+400~670+
Maximum Input Voltage (V)65
MPPT Voltage Range (V)16~60
Start Voltage (V)22
Maximum Input Current (A)152×15
Maximum Input Short-Circuit Current (A)252×25
Number of MPPTs12
Maximum MPPT Inputs per Channel1
Output (AC)
Rated Output Power (VA)450900
Rated Output Current (A)2.054.09
Output Voltage / Range (V)220 / 180~275
Rated Frequency / Range (Hz)50 / 45~55
Adjustable Power Factor (at Rated Power)>0.99 Default, 0.8 Leading… 0.8 Lagging
Total Harmonic Distortion (at Rated Power)<3%
Maximum Micro Inverters per Branch (2.5mm² Bus)115
Maximum Micro Inverters per Branch (4mm² Bus)157
Maximum Micro Inverters per Branch (6mm² Bus)199
Efficiency
Peak Efficiency96.5%96.50%
MPPT Efficiency99.8%99.80%
Night Power Consumption (mW)<50
Mechanical Parameters
Ambient Temperature (°C)-40~+65
Dimensions (W×H×D mm)182×164×30261×180×35.1
Weight (kg)1.753.2
Protection ClassOutdoor-IP67
Cooling ModeNatural Convection
Safety Protection FeaturesAnti-islanding Protection, Input Reverse Connection Protection, Output Short Circuit Protection, Output Overcurrent Protection, Output Overvoltage Protection, 6000V Surge Protection
FeaturesActive Power Adjustment, Reactive Power Adjustment, High Voltage Ride Through (Optional), Low Voltage Ride Through (Optional), High Frequency Transformer Isolation—
Other
Communication ModeSub-1G
Features
Active Power Adjustment, Reactive Power Adjustment, High Voltage Ride Through (Optional), Low Voltage Ride Through (Optional)—High Frequency Transformer Isolation
Other
Isolation Mode—High Frequency Transformer Electrical Isolation
Grid Connection Standard—NB/T 32004-2018